Out of Stock
$470.88- LG four way ceiling cassette
- Cooling Capacity: 24,200 Btu/h
- Cooling Power Input: 144 W
- Heating Capacity: 27,300 Btu/h
- Heating Power Input: 144 W
- Mixed Air (Cooling): 76° F WB
- Mixed Air (Heating): 59° F DB
- Refrigerant: R410A
- Refrigerant Control: EEV
- Sound Pressure: 41/38/35 dB(A)
-
$340.00
- Pioneer Multi Zone Indoor Unit
- Power Supply: 208~230V, 60Hz, 1Ph
- Cooling Capacity: 9,000 BTU/h
- Cooling SEER: 24
- Heating Capacity: 10,000 BTU/h
- Heating HSPF: 10.5
- Suitable Area: 250~350 Sq.F
- Air Flow (Hi/Med/Lo): 265 / 205 / 141 CFM
- Sound Level (Hi/Lo): 39 / 24.5 dB(A)
- Net Dimensions (WDH): 31.5 x 7.5 x 11.6 Inches
- Carton Dimensions (WDH): 34.5 x 11.2 x 14.7 Inches
- Net / Gross Weight: 18 / 22 Lbs
-
$1,348.00
- Pioneer Dual Zone Condensing Unit
- Power Supply: 208~230V, 60Hz, 1Ph
- Communication Protocol: Current Loop
- Min-Max Load Attached: 12,000~24,000 BTU/h
- Cooling Rated Capacity: 18,000 BTU/h
- Cooling Capacity Range: 4,950~23,000 BTU/h
- Cooling SEER (Ductless): 21.5 BTU/w
- Heating Rated Capacity: 19,000 BTU/h
- Heating Capacity Range: 4,900~23,000 BTU/h
- Heating HSPF (Ductless): 10.6 BTU/w
- Refrigerant Type: R410a
- Suitable Area: 600~800 Sq.F
- Sound Level: 59.5 dB(A)
- Circuit Breaker Utilized: 20A (double-pole)
- Net Dimensions (WDH): 35 x 13.5 x 26.5 Inches
- Carton Dimensions (WDH): 40.5 x 17.25 x 29.5 Inches
- Net / Gross Weight: 100 / 109 Lbs
-
$1,500.00
- Pioneer Floor Console
- Air Conditioner Heat Pump
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 500-600 Sq. Ft.
- Cooling: 12,000 BTU/h with 20.5 SEER efficiency
- Heating: 12,000 BTU/h with 10.0 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Variable Speed DC Inverter Operation Mode
- Low Ambient Unit (-13F)
-
$572.17
- Comfort Aire Mini-Split Air Handler
- Product Type: Indoor Unit
- Application:Â Heating/Cooling
- Heating Capacity (BTU): 12000
- Cooling Capacity (BTU): 12000
- SEER: 19
- EER: 10.5
- Liquid Line: 1/4″
- Suction Line: 1/2″
- Max Pipe Length (FT): 66
- Voltage: 115v
- Connection Type: Flare
- Warranty: 6 Years Compressor/5 Years Parts
-
Out of Stock
$1,261.00- Daizuki DXTH Series
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 1500-1600 Sq. Ft.
- Number of Zones: 1 Room
- Cooling: 24,000 BTU/H with 18 SEER efficiency
- Heating: 24,400 BTU/H with 9.5 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Wall Mounted Air Conditioning & Heating System
- Variable Speed DC Inverter Operation Mode
- Low Ambient Unit (-13F)
-
$788.00
- Daizuki DXTH Series
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 250-350 Sq. Ft.
- Number of Zones: 1 Room
- Cooling: 9,000 BTU/H with 20 SEER efficiency
- Heating: 9,500 BTU/H with 12 HSPF efficiency
- Voltage: 110-120
- 60Hz
- 1 Phase
- Wall Mounted Air Conditioning & Heating System
- Variable Speed DC Inverter Operation Mode
- Low Ambient Unit (-13F)
-
$1,932.00
- Daizuki DTXC Series
- DC Inverter
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 1400-1600 Sq. Ft.
- Number of Zones: 1 Room
- Voltage: 208-230
- 60Hz
- 1 Phase
- Wall Mounted Air Conditioning
- Variable Speed DC Inverter Operation Mode
- Auto Modes: Cool Only
-
Out of Stock
$1,980.00- Daizuki DXTH Series
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 1600-1800 Sq. Ft.
- Number of Zones: 1 Room
- Cooling: 36,000 BTU/H with 17 SEER efficiency
- Heating: 36,000 BTU/H with 10 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Wall Mounted Air Conditioning & Heating System
- Variable Speed DC Inverter Operation Mode
- Low Ambient Unit (-13F)
-
Out of Stock
$659.00- Daizuki DTXC Series
- DC Inverter
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 250-350 Sq. Ft.
- Number of Zones: 1 Room
- Voltage: 208-230
- 60Hz
- 1 Phase
- Wall Mounted Air Conditioning
- Variable Speed DC Inverter Operation Mode
- Auto Modes: Cool Only
-
$650.00
- Daizuki DTXC Series
- DC Inverter
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 500-600 Sq. Ft.
- Number of Zones: 1 Room
- Voltage: 208-230
- 60Hz
- 1 Phase
- Wall Mounted Air Conditioning
- Variable Speed DC Inverter Operation Mode
- Auto Modes: Cool Only
-
Out of Stock
$733.00- Daizuki DXTH Series
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 500-600 Sq. Ft.
- Number of Zones: 1 Room
- Cooling: 12,000 BTU/H with 20 SEER efficiency
- Heating: 12,000 BTU/H with 10 HSPF efficiency
- Voltage: 110-120
- 60Hz
- 1 Phase
- Wall Mounted Air Conditioning & Heating System
- Variable Speed DC Inverter Operation Mode
- Low Ambient Unit (-13F)
-
Out of Stock
$726.00- Daizuki DXTH Series
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 500-600 Sq. Ft.
- Number of Zones: 1 Room
- Cooling: 12,000 BTU/H with 20 SEER efficiency
- Heating: 12,000 BTU/H with 10 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Wall Mounted Air Conditioning & Heating System
- Variable Speed DC Inverter Operation Mode
- Low Ambient Unit (-13F)
-
Out of Stock
$922.00- Daizuki DXTH Series
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 1500-1600 Sq. Ft.
- Number of Zones: 1 Room
- Cooling: 18,000 BTU/H with 19 SEER efficiency
- Heating: 19,000 BTU/H with 10 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Wall Mounted Air Conditioning & Heating System
- Variable Speed DC Inverter Operation Mode
- Low Ambient Unit (-13F)
-
Out of Stock
$2,448.00- Everwell Central A/C Heat Pump
- Refrigerant: Pre-Charged R410a
- Bottom Return
- Top Discharge
- Application Area: Approx. 850 Sq. Ft.
- Multizone
- Cooling: 17,600 BTU/H with 15 SEER efficiency
- Heating: 17,200 BTU/H with 8.20 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Ducted Central Air Conditioning Heat Pump
- AHRI Certified
-
$2,472.00
- Everwell Central A/C Heat Pump
- Refrigerant: Pre-Charged R454B
- Flexible installation: Upflow, Downflow, or Horizontal
- Application Area: Approx. 1000 Sq. Ft.
- Multizone
- Cooling: 23,600 BTU/H with 15 SEER efficiency
- Heating: 22,200 BTU/H with 8.20 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Ducted Central Air Conditioning Heat Pump
- AHRI Certified
- A2L Safe
-
Out of Stock
$2,729.00- Everwell Central A/C Heat Pump
- Refrigerant: Pre-Charged R410a
- Bottom Return
- Top Discharge
- Application Area: Approx. 1200 Sq. Ft.
- Multizone
- Cooling: 28,600 BTU/H with 15 SEER efficiency
- Heating: 28,600 BTU/H with 8.30 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Ducted Central Air Conditioning Heat Pump
- AHRI Certified
-
$2,742.00
- Everwell Central A/C Heat Pump
- Refrigerant: Pre-Charged R454B
- Flexible installation: Upflow, Downflow, or Horizontal
- Application Area: Approx. 1450 Sq. Ft.
- Multizone
- Cooling: 34,000 BTU/H with 15 SEER efficiency
- Heating: 33,500 BTU/H with 8.30 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Ducted Central Air Conditioning Heat Pump
- AHRI Certified
- A2L Safe
-
$3,055.00
- Everwell Central A/C Heat Pump
- Refrigerant: Pre-Charged R454B
- Flexible installation: Upflow, Downflow, or Horizontal
- Application Area: Approx. 2200 Sq. Ft.
- Multizone
- Cooling: 46,000 BTU/H with 15 SEER efficiency
- Heating: 46,000 BTU/H with 8.30 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Ducted Central Air Conditioning Heat Pump
- AHRI Certified
- A2L Safe
-
Out of Stock
$3,720.00- Everwell Central A/C Heat Pump
- Refrigerant: Pre-Charged R410a
- Bottom Return
- Top Discharge
- Application Area: Approx. 2200 Sq. Ft.
- Multizone
- Cooling: 46,000 BTU/H with 15 SEER efficiency
- Heating: 46,000 BTU/H with 8.30 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Ducted Central Air Conditioning Heat Pump
- AHRI Certified
-
$3,661.00
- Everwell Central A/C Heat Pump
- Refrigerant: Pre-Charged R454B
- Flexible installation: Upflow, Downflow, or Horizontal
- Application Area: Approx. 2850 Sq. Ft.
- Multizone
- Cooling: 56,000 BTU/H with 15 SEER efficiency
- Heating: 55,000 BTU/H with 8.30 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Ducted Central Air Conditioning Heat Pump
- AHRI Certified
- A2L Safe
-
$4,518.00
- Pioneer Ceiling Concealed A/C Heat Pump
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 1350-1800 Sq. Ft.
- Cooling: 22,000~50,000 BTU/h with 17.5 SEER efficiency
- Heating: 20,500~54,000 BTU/h with 10.3 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- DC Inverter + Heat Pump in One System
-
$3,528.00
- Pioneer Ceiling Concealed A/C Heat Pump
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 900-1350 Sq. Ft.
- Cooling: 14,000~38,000 BTU/h with 16.5 SEER efficiency
- Heating: 14,000~42,000 BTU/h with 11.5 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- DC Inverter + Heat Pump in One System
-
$2,258.00
- Pioneer Ceiling Concealed A/C Heat Pump
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 650-900 Sq. Ft.
- Cooling: 11,000~24,400 BTU/h with 21.5 SEER efficiency
- Heating: 10,200~29,400 BTU/h with 11.0 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- DC Inverter + Heat Pump in One System
-
$1,778.00
- Pioneer Ceiling Concealed A/C Heat Pump
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 450-650 Sq. Ft.
- Cooling: 6,400~18,800 BTU/h with 19.0 SEER efficiency
- Heating: 6,000~18,900 BTU/h with 10.5 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- DC Inverter + Heat Pump in One System
-
Out of Stock
$1,438.00- Pioneer Ceiling Concealed A/C Heat Pump
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 350-450 Sq. Ft.
- Cooling: 4,100~12,100 BTU/h with 21.5 SEER efficiency
- Heating: 3,600~12,100 BTU/h with 11.5 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- DC Inverter + Heat Pump in One System
-
$1,337.00
- Pioneer Ceiling Concealed A/C Heat Pump
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 250-350 Sq. Ft.
- Cooling: 3,000~11,300 BTU/h with 20.5 SEER efficiency
- Heating: 4,800~13,900 BTU/h with 11.5 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- DC Inverter + Heat Pump in One System
-
$4,458.00
- Pioneer Floor / Ceiling Flex Mount Inverter
- Air Conditioner Heat Pump
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 1350-1800 Sq. Ft.
- Cooling: 21,560~55,890 BTU/h with 17.8 SEER efficiency
- Heating: 21,780~57,300 BTU/h with 11.0 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Variable Speed DC Inverter Operation Mode
- Low Ambient Unit (-13F)
-
$3,428.00
- Pioneer Floor / Ceiling Flex Mount Inverter
- Air Conditioner Heat Pump
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 900-1350 Sq. Ft.
- Cooling: 15,400~46,300 BTU/h with 16.0 SEER efficiency
- Heating: 15,560~47,100 BTU/h with 10.0 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Variable Speed DC Inverter Operation Mode
- Low Ambient Unit (-13F)
-
$2,258.00
- Pioneer Floor / Ceiling Flex Mount Inverter
- Air Conditioner Heat Pump
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 650-900 Sq. Ft.
- Cooling: 7,400~30,800 BTU/h with 20.0 SEER efficiency
- Heating: 7,800~31,240 BTU/h with 11.1 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Variable Speed DC Inverter Operation Mode
- Low Ambient Unit (-13F)
-
$1,898.00
- Pioneer Floor / Ceiling Flex Mount Inverter
- Air Conditioner Heat Pump
- Refrigerant: Pre-Charged R410a
- Accommodating line length up to 25 Ft.
- Application Area: Approx. 450-650 Sq. Ft.
- Cooling: 7,500~24,100 BTU/H with 20.0 SEER efficiency
- Heating: 7,500~24,100 BTU/H with 10.5 HSPF efficiency
- Voltage: 208-230
- 60Hz
- 1 Phase
- Variable Speed DC Inverter Operation Mode
- Low Ambient Unit (-13F)